1.
J Infect Dev Ctries ; 16(3): 418-421, 2022 03 31.
Article in English | MEDLINE | ID: covidwho-1786131

ABSTRACT

INTRODUCTION: Rapid antigen tests to detect SARS-CoV-2 virus need to be validated. The purpose of clinical validation is to place the test into the everyday working process in health care institutions. METHODOLOGY: The clinical validation of Alltest Covid19 antigen test (Alltest, China) and Vivadiag Pro SARS- CoV-2 antigen tests (Vivacheck, China) started in four Slovenian health care institutions in December as a point-of-care test. Institutions compared the results of antigen tests to Seegene Allplex™ 2019-nCoV rt-PCR assay (SeeGene, South Korea) and Cobas 6800 SARS CoV-2 rt-PCR (Roche, USA). RESULTS: Sensitivity (90.6%, 95% CI = 84.94%-94.36%) and specificity (100%, 95% CI = 99.41%-100%) of Vivadiag Pro SARS CoV-2 Ag test were observed. While validating Alltest Covid19 Ag assay we got similar results (sensitivity 94.37%, 95% CI = 89.20% - 97.54%), specificity 100% (95% CI = 98.83% - 100%). CONCLUSIONS: Vivadiag Pro SARS CoV-2 Ag test and Alltest Covid19 test proved to be a good screening tool to detect SARS-CoV-2. The accurate information about the patient's status was available almost immediately and there was no need to wait for rt-PCR results. We could prevent further spread of the SARS-CoV-2 in primary care and hospital settings.


Subject(s)
COVID-19 , SARS-CoV-2 , Antigens, Viral/analysis , COVID-19/diagnosis , COVID-19 Serological Testing , Hospitals , Humans , SARS-CoV-2/genetics , Sensitivity and Specificity
2.
Healthcare (Basel) ; 9(7)2021 Jul 09.
Article in English | MEDLINE | ID: covidwho-1308332

ABSTRACT

The clinical validation of the NADAL COVID-19 antigen test (Nal von Minden, Moers, Germany) started in eight Slovenian long-term health care facilities in October 2020. The purpose of clinical validation is to implement the test into the everyday working process in long-term care (LTC) facilities and demonstrate how it can be used to mitigate the spread of the virus in these environments. The facilities compared the results of antigen tests to the results obtained using Cobas 6800 SARS-CoV-2 real-time reverse transcription polymerase chain reaction (RT-PCR) (Roche, USA). Sensitivity (86.96%, 95% CI: 66.41-97.23%) and specificity (88.24%, 95% CI: 80.35-93.77%) of the NADAL COVID-19 antigen test were good. Rapid antigen testing served well for early detection of infection and helped to prevent and control spread of the SARS Cov2 in six out of eight LTCs. Moreover, mini-outbreaks were quickly resolved in all six LTCs. Locally validated immunochromatographic SARS-CoV-2 antigen testing can be used to contain the spread of the virus in LTCs. Antigen tests also deliver accurate information very quickly if used early with a low threshold. The NADAL COVID-19 antigen test proved to be a good screening tool to detect SARS-COV-2 in LTCs.

3.
Diagnostics (Basel) ; 11(6)2021 May 30.
Article in English | MEDLINE | ID: covidwho-1256439

ABSTRACT

The precise diagnosis of COVID-19 is of outmost importance in order to effectively treat patients and prevent SARS-CoV-2 transmission. Herein, we evaluated the sensitivity and specificity of the COVID-19 Antigen Detection Kit (Colloidal Gold-CG) compared with PCR in nasopharyngeal and nasal samples. A total of 114 positive and 244 negative nasopharyngeal specimens confirmed by PCR were used in this comparative study. When the PCR positive Cycle Threshold (Ct) value was ≤25, CG sensitivity was 100%. When the PCR positive Ct value was ≤33, CG sensitivity was 99%. When the PCR positive Ct value was ≤40, CG sensitivity was 89.47%. Regarding nasal swabs, a total of 109 positive and 250 negative specimens confirmed by PCR were used. When the PCR positive Ct value was ≤25, CG sensitivity was 100%. When the PCR positive Ct value was ≤33, CG sensitivity was 96.12%. When the PCR positive Ct value was ≤37, CG sensitivity was 91.74%. Specificity was above 99% regardless of the Ct value of PCR positivity for both nasopharyngeal and nasal specimens. Overall, the CG showed high sensitivity and specificity when the PCR Ct value was less than 33. Therefore, CG can be used for screening early in the disease course. Confirmatory PCR is essential when a false negative result is suspected.